Parsons Xtra mining chains have been developed using Parsons Chain’s expertise in materials technology and heat treatment techniques. First developed 20 years ago as ‘Enhanced’ chain the range is reliable and well proven at those mines where operational conditions are suitable for high specification chain.

Xtra chain offers higher tensile strength, longer fatigue life and increased toughness properties when compared with chain conforming with the latest DIN specifications for round and flat link chain. Optimum hardness profiles for each link reduce interlink wear giving significantly increased operational life. 

 

 Xtra_Increase_Mechanical_Graph1  Xtra_Increase_Graph

 

Round Link Xtra Mining Chains - Mechanical Properties

 

Nominal Size

d x t

Reference Number Test Force
TF
Breaking Force

BF
Operating Force
WF
Bend Test deflection -min Fatigue Cycles
kN
mm kN kN - MAX mm min typical
22 x 86 22086RXR 525 745 456 22 200,000 >500,000
26 x 92 26092RXR 733 1040 637 26
30 x 108 30108RXR 976 1390 848 30
34 x 126 34126RXR 1250 1780 1090 34
38 x 137 38137RXR 1560 2220 1360 38
Reference Numbering System
38137
R
X
R
Size and Pitch
Round Link
Xtra Specification
Rust Preventative
Elongation at test force - 1.6% max
Total elongation at fracture - 14% min
Impact KV Test - 50J. min.
Refer to DIN22252:2001 for verification methods and procedures

 

 

 Compact Xtra Mining Chains - Mechanical Properties
Nominal Size
d x t
Reference Number Test Force
TF
Breaking Force
BF
Operating Force
WF
Bend Test deflection -min Fatigue Cycles
Kn
mm kN kN - MAX mm min typical
34 x 126 34126CXRW/F 1250 1780 1090 34 125,000 >200,000
38 x 126 38126CXRW/F 1560 2220 1360 38
38 x 137 38137CXRW/F 1560 2220 1360 38
38 x 146 38146CXRW/F 1560 2220 1360 38
42 x 146 42146CXRW/F 1910 2720 1660 42
48 x 152 48152CXRW/F 2500 3550 2170 48
Reference Numbering System
48152
C
X
R
W
F
Size and Pitch
Compact Link
Xtra Specification
Rust Preventative
Welded End Links
Forged (Vertical) End Links
Elongation at test force - 1.6% max
Total elongation at fracture - 11% min
Impact KV Test - 50J. min.
Refer to DIN22255:2001 for verification methods and procedures
   
   
 